JM

"John Marshall"

15/11/2005 6:38 AM

coverting motors to 240 v.

Am considering changing my table saw and dust collector to 240v. from 120v.
Will any difference in power be achieved. Advantages and disadvantages in
doing this?
Thanks, John M.


This topic has 3 replies

Do

"Duke of Burl"

in reply to "John Marshall" on 15/11/2005 6:38 AM

15/11/2005 6:42 AM

All things being equal, you can do longer runs with the same size wire.
Downsize is using more spaces in your sub-panel. Power won't be any
different unless your 120v wire is undersized now or you have one of
those Delta's with different windings on the motor.

PC

Patrick Conroy

in reply to "John Marshall" on 15/11/2005 6:38 AM

16/11/2005 11:40 PM

"John Marshall" <[email protected]> wrote in
news:[email protected]:

>
>
> Am considering changing my table saw and dust collector to 240v. from
> 120v. Will any difference in power be achieved. Advantages and
> disadvantages in doing this?
> Thanks, John M.
>
>

I did both my TS and DC a month or so ago. The advantages to me were (1) TS
spins up faster (2) DC stopped popping breakers.

DW

"Dave W"

in reply to "John Marshall" on 15/11/2005 6:38 AM

15/11/2005 8:38 AM

You will see the same or slightly better performance from your machinery.
The advantage is that the current to the machines will be less allowing the
safe use of smaller wire size (as in cost of copper). If the wire size is
marginal now, you may see significant performance increase after the change
to 240V.
Dave


You’ve reached the end of replies