"Mike in Arkansas"

11/02/2005 8:08 PM

Is this a suitable blower for a dust collection system??? It really blows

Wondering if this blower is usable in a dust collecion system. Looks
about right to me but I'm asking the experts here. Pictures are at:
http://img.photobucket.com/albums/v697/mike72903/52bb828b.jpg
http://img.photobucket.com/albums/v697/mike72903/blowerbigger.jpg
http://img.photobucket.com/albums/v697/mike72903/blowercover.jpg
Dimensions are: diameter 11 inches. Opening in housing with cover
removed as pictured is 8 inches. Opening in cover shown in last
picture is 4 inches. Outlet is 2 1/2 inches. Motor is an AO Smith 1/2
HP 9.5 amp motor at 115 volts or 4.8 amps at 230 volts and 3450 RPM
It was installed in an air sampleing system and was adjusted to provide
1000 CFM through a 4 inch pipe. It will do more than that as the
outlet was restricted with a gate valve to get the 1000 but I don't
know what the max is. I ran it briefly with the cover off as pictured
and I could feel the suction when I got close. It was scary. What do
you think, worth a shot? Meanwhile I'll DAGS and see what else is
involved with a homemade collector. One final question. Noise issue
and sawdust piles aside, could a dust collector just be vented outside
rather than into a bag or chip collector. Thank you kindly gentlemen


This topic has 19 replies

LJ

Larry Jaques

in reply to "Mike in Arkansas" on 11/02/2005 8:08 PM

12/02/2005 7:38 AM

On Sat, 12 Feb 2005 01:16:32 -0800, the inscrutable Fly-by-Night CC
<[email protected]> spake:

>In article <[email protected]>,
> "Mike in Arkansas" <[email protected]> wrote:
>
>> What do
>> you think, worth a shot?
>
>I don't see why not - what have you got to lose by giving it a try?
>
>> One final question. Noise issue
>> and sawdust piles aside, could a dust collector just be vented outside
>> rather than into a bag or chip collector.
>
>Sure as long as you don't mind the dust settling on everything in the
>immediate area.

Wait'll his wife hangs the laundry while he's in the shop...

--
Vidi, Vici, Veni
---
http://diversify.com Comprehensive Website Development

Dd

"Doug"

in reply to "Mike in Arkansas" on 11/02/2005 8:08 PM

12/02/2005 5:46 AM

I faced the exact same situation a few years ago. I had a blower, very
similar, from an old forced hot air furnace. I decided I could convert
it into a dust collector. The short of the story is that I spent neary
$100 dollars, wound up frustrated, wasted a lot of spare time that I
could have been WWing with, or installing a real DC. If you are
planning to build a portable unit, that might be one thing, but if you
want to have a centalized system at all (i.e. running ducting to your
machines) you'll find that 1/2 horse (despite the fact that it feels
like it has a lot of suction) is way underpowered. I eventually spent
$150 on the harbor frieght 2 horse, 20 amp unit, and like a lot of
people, I am very satisfied with it. Once you hook up any lengths of
ducting to that thing you've got, you'll soon find how inadequate the
power will be. I also believe you write that your's has only a 2 1/2
inlet??

I only say this because of my personal experience trying to do exactly
what you are considering. Don't bother!


Mike in Arkansas wrote:
> Wondering if this blower is usable in a dust collecion system. Looks
> about right to me but I'm asking the experts here. Pictures are at:
> http://img.photobucket.com/albums/v697/mike72903/52bb828b.jpg
> http://img.photobucket.com/albums/v697/mike72903/blowerbigger.jpg
> http://img.photobucket.com/albums/v697/mike72903/blowercover.jpg
> Dimensions are: diameter 11 inches. Opening in housing with cover
> removed as pictured is 8 inches. Opening in cover shown in last
> picture is 4 inches. Outlet is 2 1/2 inches. Motor is an AO Smith
1/2
> HP 9.5 amp motor at 115 volts or 4.8 amps at 230 volts and 3450 RPM
> It was installed in an air sampleing system and was adjusted to
provide
> 1000 CFM through a 4 inch pipe. It will do more than that as the
> outlet was restricted with a gate valve to get the 1000 but I don't
> know what the max is. I ran it briefly with the cover off as
pictured
> and I could feel the suction when I got close. It was scary. What
do
> you think, worth a shot? Meanwhile I'll DAGS and see what else is
> involved with a homemade collector. One final question. Noise issue
> and sawdust piles aside, could a dust collector just be vented
outside
> rather than into a bag or chip collector. Thank you kindly gentlemen

Mi

"Mike in Arkansas"

in reply to "Mike in Arkansas" on 11/02/2005 8:08 PM

12/02/2005 9:52 AM

Okay, okay, venting to the outside is out :) Going to plan to use but
Im a little confused about horsepower. If it will move more than 1200
CFM now at 3450 RPM with 1/2 hp, how will increasing the hp help?
Seems like a lot of the DC's are rated at less than 1000 CFM. Do I
need the hp to overcome piping length? Thanks for everyones input

Dd

"Doug"

in reply to "Mike in Arkansas" on 11/02/2005 8:08 PM

12/02/2005 6:09 PM

I'm not sure where you're getting your CFM rating. It seems very high.
When I tried to build mine, the problem was not that the motor could
not turn the impeller enough to create a lot of wind-- it did! But I
soon discovered that the motor was drawing too many amps and it
eventually would begin to overheat. It was simply being strained. And
yes, as you add ducting, you will increase the stress on the motor.

I suppose if you were thinking about just blowing all of the dust out
the window, it might be worth a try. I was trying to contain the dust,
so my added expenses included an attempt to add DC bags, etc. .

Again, though, if the whole thing is going to funnel down to 2 1/2
inch inlet, I really just don't think it will be too effective. Good
luck. I'd be curious to see if you can make it work without too much
frustration or expense. Let us know.


Mike in Arkansas wrote:
> Okay, okay, venting to the outside is out :) Going to plan to use
but
> Im a little confused about horsepower. If it will move more than
1200
> CFM now at 3450 RPM with 1/2 hp, how will increasing the hp help?
> Seems like a lot of the DC's are rated at less than 1000 CFM. Do I
> need the hp to overcome piping length? Thanks for everyones input

Mi

"Mike in Arkansas"

in reply to "Mike in Arkansas" on 11/02/2005 8:08 PM

14/02/2005 2:48 PM

Okay, my apologies. I am an uneducated dolt that has CRS real bad.
Memory failed and the 1000 CMF figure I was quoting was actually 1000
feet per minute VELOCITY. Since this was 1000 feet per minute through a
4 inch tube, I believe that works out to about 85 CFM. Managed to get
my hands on a spec sheet for this blower and maximum CFM free delivery
is only 350 CFM. So those that said it was too small for a shop wide
DC were correct. Dang! As always, I appreciate very much the input
from everyone.

Mi

"Mike in Arkansas"

in reply to "Mike in Arkansas" on 11/02/2005 8:08 PM

14/02/2005 9:07 PM

Sorry about that OldNick. Your critical thinking was appreciated and
spot on. I still might try using it as a single machine
DC for a jointer or planer. Put a bag on the outlet and mount it on a
trash can seperator and see what happens. Again, Im sorry, I did not
intend to make anyone waste their time. In fact, I knew about the 1000
fpm velocity figure because I had need to work on this very problem
just a couple of months ago using this very fan. Using a pitot tube and
micromanometer, I adjusted the outlet restriction to produce the said
velocity in an air sampler system. To quote you "gaaah"!
Mike in Arkansas who as he nears the age of 60 is losing his frigging
mind.

On

OldNick

in reply to "Mike in Arkansas" on 11/02/2005 8:08 PM

15/02/2005 10:40 AM

On 14 Feb 2005 14:48:21 -0800, "Mike in Arkansas" <[email protected]>
vaguely proposed a theory
......and in reply I say!:

remove ns from my header address to reply via email

> Okay, my apologies. I am an uneducated dolt that has CRS real bad.
>Memory failed and the 1000 CMF figure I was quoting was actually 1000
>feet per minute VELOCITY. Since this was 1000 feet per minute through a
>4 inch tube, I believe that works out to about 85 CFM. Managed to get
>my hands on a spec sheet for this blower and maximum CFM free delivery
>is only 350 CFM. So those that said it was too small for a shop wide
>DC were correct. Dang! As always, I appreciate very much the input
>from everyone.


gaaah! I just spent a half hour sorting ouyt and posting a great deal
of stuff! <G>

JJ

JGS

in reply to "Mike in Arkansas" on 11/02/2005 8:08 PM

12/02/2005 5:42 AM

Hi Mike,
As far as venting to the out of doors it's a good idea from the health
prospective as the bags and filters let the smaller particles escape back
into the room. Another down side, depending upon how long you run it, is
heating / cooling the shop. Cheers, JG

Mike in Arkansas wrote:

> Wondering if this blower is usable in a dust collecion system. Looks
> about right to me but I'm asking the experts here. Pictures are at:
> http://img.photobucket.com/albums/v697/mike72903/52bb828b.jpg
> http://img.photobucket.com/albums/v697/mike72903/blowerbigger.jpg
> http://img.photobucket.com/albums/v697/mike72903/blowercover.jpg
> Dimensions are: diameter 11 inches. Opening in housing with cover
> removed as pictured is 8 inches. Opening in cover shown in last
> picture is 4 inches. Outlet is 2 1/2 inches. Motor is an AO Smith 1/2
> HP 9.5 amp motor at 115 volts or 4.8 amps at 230 volts and 3450 RPM
> It was installed in an air sampleing system and was adjusted to provide
> 1000 CFM through a 4 inch pipe. It will do more than that as the
> outlet was restricted with a gate valve to get the 1000 but I don't
> know what the max is. I ran it briefly with the cover off as pictured
> and I could feel the suction when I got close. It was scary. What do
> you think, worth a shot? Meanwhile I'll DAGS and see what else is
> involved with a homemade collector. One final question. Noise issue
> and sawdust piles aside, could a dust collector just be vented outside
> rather than into a bag or chip collector. Thank you kindly gentlemen

EJ

"Eric J. Comeau"

in reply to "Mike in Arkansas" on 11/02/2005 8:08 PM

13/02/2005 11:25 PM

This blower should work with the cover but the motor is small. Maybe if you
get a drum with a cover. In the cover have an inlet from your machines and
the outlet hooked up to the blower. At least the large particles should
stay in the drum and only the finer particles would go through the the
blower. All those heavy particles could quickly kill that small motor.

One guy mentioned a furnace fan, those are squirrel cage fans and will not
work on any solid particles. They are made for air only. The shavings and
other large pieces would get caught in the fins and quickly make it out of
balance.

Good luck. If you get a bigger motor you could install the impeller on a
shaft with two pillow blocks and belt drive it. That way you could slow it
down if needed.
"Mike in Arkansas" <[email protected]> wrote in message
news:[email protected]...
> Wondering if this blower is usable in a dust collecion system. Looks
> about right to me but I'm asking the experts here. Pictures are at:
> http://img.photobucket.com/albums/v697/mike72903/52bb828b.jpg
> http://img.photobucket.com/albums/v697/mike72903/blowerbigger.jpg
> http://img.photobucket.com/albums/v697/mike72903/blowercover.jpg
> Dimensions are: diameter 11 inches. Opening in housing with cover
> removed as pictured is 8 inches. Opening in cover shown in last
> picture is 4 inches. Outlet is 2 1/2 inches. Motor is an AO Smith 1/2
> HP 9.5 amp motor at 115 volts or 4.8 amps at 230 volts and 3450 RPM
> It was installed in an air sampleing system and was adjusted to provide
> 1000 CFM through a 4 inch pipe. It will do more than that as the
> outlet was restricted with a gate valve to get the 1000 but I don't
> know what the max is. I ran it briefly with the cover off as pictured
> and I could feel the suction when I got close. It was scary. What do
> you think, worth a shot? Meanwhile I'll DAGS and see what else is
> involved with a homemade collector. One final question. Noise issue
> and sawdust piles aside, could a dust collector just be vented outside
> rather than into a bag or chip collector. Thank you kindly gentlemen
>

EP

"Edwin Pawlowski"

in reply to "Mike in Arkansas" on 11/02/2005 8:08 PM

12/02/2005 2:37 PM


>> One final question. Noise issue
>> and sawdust piles aside, could a dust collector just be vented outside
>> rather than into a bag or chip collector.

Sure can, but there are other issues. Wife, neighbors, open windows on your
car, When I bought my Delta planer I did not have a duct collector. I
figured I try running it outside the garage. I planed one board and bought
a DC. There was chips all over the place. Your DC will do the same and
make an ugly looking mess. If you happen to live in a cave near the town
dump, go for it. If you live in a decent house, well, you get the idea.
--
Ed
http://pages.cthome.net/edhome/

tt

"toller"

in reply to "Mike in Arkansas" on 11/02/2005 8:08 PM

12/02/2005 5:26 PM

I would use it. The expensive part of a DC is the impeller. Yours is
bigger than normal, and the bigger the better. Sure, the motor is too
small, but you can always upgrade that later.

EP

"Edwin Pawlowski"

in reply to "Mike in Arkansas" on 11/02/2005 8:08 PM

12/02/2005 6:08 PM


"Mike in Arkansas" <[email protected]> wrote in message
news:[email protected]...
> Okay, okay, venting to the outside is out :) Going to plan to use but
> Im a little confused about horsepower. If it will move more than 1200
> CFM now at 3450 RPM with 1/2 hp, how will increasing the hp help?
> Seems like a lot of the DC's are rated at less than 1000 CFM. Do I
> need the hp to overcome piping length? Thanks for everyones input

My guess is the blower you have is rated free standing, not configured into
a machine that will cause static pressure and require more power to move the
same cfm. When you put some tubing and bags on the other end it would make a
difference.

c

in reply to "Mike in Arkansas" on 11/02/2005 8:08 PM

14/02/2005 2:54 PM

Mike...

Nobody seems to have suggested it yet, so I'll give it a whirl. You
ought to take a look at Bill Pentz's page here:

http://billpentz.com/woodworking/cyclone/Blower.cfm

You might even try emailing Bill and tell him what you want to do.
Getting a good air mover seems to be the crux of building a good DC
setup, and while yours sounds underpowered for even one machine, you
could put a 1.5 or 2 HP motor on it and combined with a cyclone, you'd
have a very efficient and powerful system.

You might also want to look at this:

http://cgi.ebay.com/ws/eBayISAPI.dll?ViewItem&item=4355524814

BTW, you can buy a 3/4 HP DC unit complete with bag at Lowes for $99,
so before you go nuts, look around.

Mike


On 11 Feb 2005 20:08:47 -0800, "Mike in Arkansas" <[email protected]>
wrote:

>Wondering if this blower is usable in a dust collecion system. Looks
>about right to me but I'm asking the experts here. Pictures are at:
>http://img.photobucket.com/albums/v697/mike72903/52bb828b.jpg
>http://img.photobucket.com/albums/v697/mike72903/blowerbigger.jpg
>http://img.photobucket.com/albums/v697/mike72903/blowercover.jpg
>Dimensions are: diameter 11 inches. Opening in housing with cover
>removed as pictured is 8 inches. Opening in cover shown in last
>picture is 4 inches. Outlet is 2 1/2 inches. Motor is an AO Smith 1/2
>HP 9.5 amp motor at 115 volts or 4.8 amps at 230 volts and 3450 RPM
>It was installed in an air sampleing system and was adjusted to provide
>1000 CFM through a 4 inch pipe. It will do more than that as the
>outlet was restricted with a gate valve to get the 1000 but I don't
>know what the max is. I ran it briefly with the cover off as pictured
>and I could feel the suction when I got close. It was scary. What do
>you think, worth a shot? Meanwhile I'll DAGS and see what else is
>involved with a homemade collector. One final question. Noise issue
>and sawdust piles aside, could a dust collector just be vented outside
>rather than into a bag or chip collector. Thank you kindly gentlemen

On

OldNick

in reply to "Mike in Arkansas" on 11/02/2005 8:08 PM

15/02/2005 10:39 AM

On 12 Feb 2005 09:52:37 -0800, "Mike in Arkansas" <[email protected]>
vaguely proposed a theory
......and in reply I say!:

remove ns from my header address to reply via email

Ok. I have been giving this some thought.

When you add piping, the power use will _drop_.

But if you add piping, the flow will also drop.

Machines not drawing any air need very little power to run. The motor
is essentially idling.

The only way I can see that your 1/2HP machine was dragging 1000CFM
(if that's what you actually saw it do) is that it is doing it only at
extremely small pressure differentials. This will have to do with the
design of the fan. I am not up with the finer details, but have looked
at water pumps a bit. Rotor design is critical to decide high flow,
high pressure etc. Either can be done with lower horsepower, if the
other is largely ignored. For instance there are bilge pumps that move
huge quantities of water, say 400 - 200 GPH, drawing only a few amps
at 12V. But their lift is maybe 3-4'.

Your setup may draw the claimed 1000CFM through the 9" opening without
any ducting.

Had a look at some tables (neat little set of software charts called
Engineering Power Tools). According to me, to drag 1000CFM of air
through 60' of 4" pipe would need 3.5 Hp straight and 5 Hp or more
with 3 elbows.

So adding HP may _not_ work. You will still spin the blower at the
same speed, and it will still move its 1000CFm, but when you add
piping (= "head" of pressure) you will simply not suck anything.

I would suggest getting a longish length, say 2-3 x 20' of 4" storm
pipe and a couple or three of elbows, and see what happens when you
try to draw through them. If you are happy then you are happy, and I
need to rethink my above BS! <G>

>Okay, okay, venting to the outside is out :) Going to plan to use but
>Im a little confused about horsepower. If it will move more than 1200
>CFM now at 3450 RPM with 1/2 hp, how will increasing the hp help?
>Seems like a lot of the DC's are rated at less than 1000 CFM. Do I
>need the hp to overcome piping length? Thanks for everyones input

On

OldNick

in reply to "Mike in Arkansas" on 11/02/2005 8:08 PM

14/02/2005 7:18 AM

On Sun, 13 Feb 2005 22:28:39 GMT, Dale Scroggins <[email protected]>
vaguely proposed a theory
......and in reply I say!:

remove ns from my header address to reply via email

>Doug wrote:
>> I'm not sure where you're getting your CFM rating. It seems very high.

Agreed <G>


>Centrifugal blowers are a little counter-intuitive.


Agreed, and all most unfair! <G>

On

OldNick

in reply to "Mike in Arkansas" on 11/02/2005 8:08 PM

15/02/2005 3:45 PM

On 14 Feb 2005 21:07:14 -0800, "Mike in Arkansas" <[email protected]>
vaguely proposed a theory
......and in reply I say!:

remove ns from my header address to reply via email

I was just kidding. It was an interesting exercise. I thought it was
rather good. Everybody running around trying to work out HTF, and
nobody even came up with the 1000FPM! <G>

Only comment is, use as big a bag as you can. My 1HP unit has two
bags, maybe 2' high and 18" diameter?? It's still only considered a
1-machine machine. The bigger the bag the better the suction for a
given fineness of mesh.

>Sorry about that OldNick. Your critical thinking was appreciated and
>spot on. I still might try using it as a single machine
>DC for a jointer or planer. Put a bag on the outlet and mount it on a
>trash can seperator and see what happens. Again, Im sorry, I did not
>intend to make anyone waste their time. In fact, I knew about the 1000
>fpm velocity figure because I had need to work on this very problem
>just a couple of months ago using this very fan. Using a pitot tube and
>micromanometer, I adjusted the outlet restriction to produce the said
>velocity in an air sampler system. To quote you "gaaah"!
>Mike in Arkansas who as he nears the age of 60 is losing his frigging
>mind.

FC

Fly-by-Night CC

in reply to "Mike in Arkansas" on 11/02/2005 8:08 PM

12/02/2005 1:16 AM

In article <[email protected]>,
"Mike in Arkansas" <[email protected]> wrote:

> What do
> you think, worth a shot?

I don't see why not - what have you got to lose by giving it a try?

> One final question. Noise issue
> and sawdust piles aside, could a dust collector just be vented outside
> rather than into a bag or chip collector.

Sure as long as you don't mind the dust settling on everything in the
immediate area.

--
Owen Lowe and his Fly-by-Night Copper Company
____

"Sure we'll have fascism in America, but it'll come disguised
as 100% Americanism." -- Huey P. Long

DS

Dale Scroggins

in reply to "Mike in Arkansas" on 11/02/2005 8:08 PM

13/02/2005 10:28 PM

Doug wrote:
> I'm not sure where you're getting your CFM rating. It seems very high.
> When I tried to build mine, the problem was not that the motor could
> not turn the impeller enough to create a lot of wind-- it did! But I
> soon discovered that the motor was drawing too many amps and it
> eventually would begin to overheat. It was simply being strained. And
> yes, as you add ducting, you will increase the stress on the motor.

Centrifugal blowers are a little counter-intuitive. Adding restrictions
to the input or outlet will actually reduce the load on the motor. Try
it on your shop vac. Plug the hose and listen to the motor speed up
slightly. If you had an ammeter hooked into the power circuit, you
would note a drop in current with the inlet hose blocked.

Motor current consumed by a centrifugal blower (or any fan, for that
matter) is directly proportional to the amount of air being moved. If
the air flow is reduced, so is the motor current. Adding filters,
ducts, gates, etc. will reduce the CFM of the system, and drop the
current demand of the motor. It would run cooler.


> I suppose if you were thinking about just blowing all of the dust out
> the window, it might be worth a try. I was trying to contain the dust,
> so my added expenses included an attempt to add DC bags, etc. .

It would actually put more load on the motor to run without bags, etc.
See above.

> Again, though, if the whole thing is going to funnel down to 2 1/2
> inch inlet, I really just don't think it will be too effective. Good
> luck. I'd be curious to see if you can make it work without too much
> frustration or expense. Let us know.

The impeller is a little small compared to most commercially available
collectors, but could work if only one tool is in use at a time. Since
both the impeller and its housing appear to be made from aluminum,
running it without a cyclonic separator could result in some rapid
erosion. It does have a substantially larger impeller than most shop
vacs, so it should produce higher CFM than they would.

>
> Mike in Arkansas wrote:
>
>>Okay, okay, venting to the outside is out :) Going to plan to use
>
> but
>
>>Im a little confused about horsepower. If it will move more than
>
> 1200
>
>>CFM now at 3450 RPM with 1/2 hp, how will increasing the hp help?
>>Seems like a lot of the DC's are rated at less than 1000 CFM. Do I
>>need the hp to overcome piping length? Thanks for everyones input
>
Your CFM will be limited by impeller size and speed, not motor HP.
Speeding up the impeller probably won't help much, and at some point
will actually reduce airflow. Your motor and impeller seem well
matched, and added restrictions will actually reduce the load on the
motor. See above.

Dust collection systems SHOULD be rated as used; that is, with filters,
ducts, gates, etc. in place. Free air ratings would be of little use.
Your CFM may drop considerably when all that stuff is connected to the
blower.

Dale Scroggins
also in Arkansas

On

OldNick

in reply to "Mike in Arkansas" on 11/02/2005 8:08 PM

14/02/2005 7:16 AM

On 11 Feb 2005 20:08:47 -0800, "Mike in Arkansas" <[email protected]>
vaguely proposed a theory
......and in reply I say!:

remove ns from my header address to reply via email

>Motor is an AO Smith 1/2
>HP

Unless there is some magic at work here, that is the stopper. Most
halfway decent DCs _start_ at a 1 HP motor. 2HP is better. 1HP ones
would service maybe 2 machines, but are best wheeled around the shop
to each machine. I think that you will find that the fan part of this
will be designed to load the motor OK, but not to move the air needed
to be a DC.

On the other hand, if it was getting 1000 CFM through a 4" pipe....
shrug....magic.

Could somebody expand on that for me? Maybe it just moves huge amounts
of air, but with no real pressure?