Subject: How to hook up a dust collector in this circumstance.
Date: Wednesday, January 24, 2007 11:11 AM
Hi,
I need a bit of help with hooking up a dust collector. As it stands
right now my ducts will run in an 'L' pattern, 10' on each length. The
DC will be where the 10' lengths meet.
I'm using spiral ducts hanging from the ceiling. Do I use a 'T'
connector where the 2 10' lengths meet and drop down another spiral
down to the DC. I'm wondering how to handle the 90 degree transition.
Thanks
Alex
With the D/C at the junction of your two 10-foot runs, try to have each run
terminate above the D/C using a 45deg. transition. Can you get the two
transitions to meet into a wye? If so, use that wye, then another 45deg.
transition (to point straight down). Continue to the cyclone as directly as
possible.